Pick what you want to run during load-shedding and your battery size, and see roughly how many hours your UPS or inverter will last.
What will you run? (tap + to add)
How backup time is worked out
Battery energy (Wh) = Ah × volts × number of batteries. You can’t use all of it: lead-acid and tubular batteries last longer if you only use about 50%, while lithium batteries can use about 90%. The inverter also loses some power (about 15%). So:
Backup hours = Ah × V × batteries × usable % × 0.85 ÷ load (W)
Example: one 12V 200Ah tubular battery running 250W gives 12 × 200 × 0.5 × 0.85 ÷ 250 ≈ 4 hours.
Tips for longer backup
- Use DC or inverter fans and LED lights; they use far less power.
- Keep the router on its own small DC UPS or a power bank with 12V output.
- Charge phones from a power bank during load-shedding to save UPS power.
- Real time changes with battery age, temperature and how full the battery is.
Frequently asked questions
How long will a 150Ah battery run a fan?
A ceiling fan uses about 70–80W. One 12V 150Ah lead-acid battery at 50% usable gives about 12 × 150 × 0.5 × 0.85 ÷ 75 ≈ 10 hours for one fan.
Why can’t I use the full battery capacity?
Draining lead-acid and tubular batteries below about half shortens their life a lot. Lithium batteries handle deeper use, so they give more backup from the same Ah.
Does a bigger inverter give more backup?
No. Backup depends on battery size and how much load you run. The inverter rating only decides the maximum load it can handle.